AWK-3131A

Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client

Producător: MOXA
Producător: MOXA
  •  IEEE 802.11a/b/g/n AP/bridge/client support
  •  Easy setup and deployment with AeroMag
  •  Millisecond-level Client-based Turbo Roaming 
  •  Complete redundancy with AeroLink Protection
  •  Easy network setup with Network Address Translation (NAT)
  •  Integrated antenna and power isolation
  •  -40 to 75°C wide operating temperature range (-T models)
  •  5 GHz DFS channel support
Preț de la 3.170,00 RON Net

Preț prea mare? Autentificați-vă și cumpărați mai ieftin

În livrare

Livrare gratuita de la 500 RON

Vezi 2 model

Promocja cenowa na model HDR-15-5

Produs destinat exclusiv utilizării profesionale

Modele

Descriere

The AWK-3131A 3-in-1 industrial wireless AP/bridge/client meets the growing need for faster data transmission speeds by supporting IEEE 802.11n technology with a net data rate of up to 300 Mbps. The AWK-3131A is compliant with industrial standards and approvals covering operating temperature, power input voltage, surge, ESD, and vibration. The two redundant DC power inputs increase the reliability of the power supply, and the AWK-3131A can be powered via PoE to make deployment easier. The AWK-3131A can operate on either the 2.4 or 5 GHz bands and is backwards-compatible with existing 802.11a/b/g deployments to future-proof your wireless investments.

Advanced 802.11n Industrial Wireless Solution

  • 802.11a/b/g/n compliant AP/bridge/client for flexible deployment
  • Software optimized for long-distance wireless communication with up to 1 km line of sight and external high-gain antenna (available only on 5 GHz)
  • Supports 60 clients connected concurrently
  • DFS channel support allows a wider range of 5 GHz channel selection to avoid interference from existing wireless infrastructure

Advanced Wireless Technology

  • AeroMag supports error-free setup of your industrial applications’ fundamental WLAN settings
  • Seamless roaming with client-based Turbo Roaming  for < 150 ms roaming recovery time between APs (Client Mode)
  • Supports AeroLink Protection for creating a redundant wireless link (< 300 ms recovery time) between APs and their clients

Industrial Ruggedness

  • Integrated antenna and power isolation designed to provide 500 V insulation protection against external electrical interference
  • Hazardous location wireless communication with Class I Div. II and ATEX Zone 2 certifications
  • -40 to 75°C wide operating temperature models (-T) provided for smooth wireless communication in harsh environments

Specificație tehnică

  • WLAN Interface
WLAN Standards 802.11a/b/g/n
802.11i Wireless Security
Modulation Type DSSS
OFDM
MIMO-OFDM
Frequency Band for US (20 MHz operating channels) 2.412 to 2.462 GHz (11 channels)
5.180 to 5.240 GHz (4 channels)
5.260 to 5.320 GHz (4 channels) *
5.500 to 5.700 GHz (11 channels) *
5.745 to 5.825 GHz (5 channels)
Frequency Band for EU (20 MHz operating channels) 2.412 to 2.472 GHz (13 channels)
5.180 to 5.240 GHz (4 channels)
5.260 to 5.320 GHz (4 channels) *
5.500 to 5.700 GHz (11 channels)*
Frequency Band for JP (20 MHz operating channels) 2.412 to 2.484 GHz (14 channels)
5.180 to 5.240 GHz (4 channels)
5.260 to 5.320 GHz (4 channels) *
5.500 to 5.700 GHz (11 channels) * 
  * DFS (Dynamic Frequency Selection) channel support: In AP mode, when a radar signal is detected, the device will automatically switch to another channel. However, according to regulations, after switching channels, a 60-second availability check period is required before starting the service.
Wireless Security WEP encryption (64-bit and 128-bit)
WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, TKIP, AES)
WPA/WPA2-Personal
Transmission Rate 802.11b: 1 to 11 Mbps
802.11a/g: 6 to 54 Mbps
802.11n: 6.5 to 300 Mbps
Transmitter Power for 802.11a 23±1.5 dBm @ 6 to 24 Mbps
21±1.5 dBm @ 36 Mbps
20±1.5 dBm @ 48 Mbps
18±1.5 dBm @ 54 Mbps
Transmitter Power for 802.11n (5 GHz) 23±1.5 dBm @ MCS0/8 20 MHz
18±1.5 dBm @ MCS7/15 20 MHz
23±1.5 dBm @ MCS0/8 40 MHz
17±1.5 dBm @ MCS7/15 40 MHz
Transmitter Power for 802.11b 26±1.5 dBm @ 1 Mbps
26±1.5 dBm @ 2 Mbps
26±1.5 dBm @ 5.5 Mbps
25±1.5 dBm @ 11 Mbps
Transmitter Power for 802.11g 23±1.5 dBm @ 6 to 24 Mbps
21±1.5 dBm @ 36 Mbps
19±1.5 dBm @ 48 Mbps
18±1.5 dBm @ 54 Mbps
Transmitter Power for 802.11n (2.4 GHz) 23±1.5 dBm @ MCS0/8 20 MHz
18±1.5 dBm @ MCS7/15 20 MHz
23±1.5 dBm @ MCS0/8 40 MHz
17±1.5 dBm @ MCS7/15 40 MHz
Receiver Sensitivity for 802.11a (measured at 5.680 GHz) Typ. -90 @ 6 Mbps
Typ. -88 @ 9 Mbps
Typ. -88 @ 12 Mbps
Typ. -85 @ 18 Mbps
Typ. -81 @ 24 Mbps
Typ. -78 @ 36 Mbps
Typ. -74 @ 48 Mbps
Typ. -72 @ 54 Mbps
Note: Due to a limitation in the receiver sensitivity performance for channels 153 and 161, it is recommended to avoid using these channels in your critical applications.
Receiver Sensitivity for 802.11n (5 GHz; measured at 5.680 GHz) Typ. -69 dBm @ MCS7 20 MHz
Typ. -71 dBm @ MCS15 20 MHz
Typ. -63 dBm @ MCS7 40 MHz
Typ. -68 dBm @ MCS15 40 MHz
Note: Due to a limitation in the receiver sensitivity performance for channels 153 and 161, it is recommended to avoid using these channels in your critical applications.
Receiver Sensitivity for 802.11b (measured at 2.437 GHz) Typ. -93 dBm @ 1 Mbps
Typ. -93 dBm @ 2 Mbps
Typ. -93 dBm @ 5.5 Mbps
Typ. -88 dBm @ 11 Mbps
Receiver Sensitivity for 802.11g (measured at 2.437 GHz) Typ. -88 dBm @ 6 Mbps
Typ. -86 dBm @ 9 Mbps
Typ. -85 dBm @ 12 Mbps
Typ. -85 dBm @ 18 Mbps
Typ. -85 dBm @ 24 Mbps
Typ. -82 dBm @ 36 Mbps
Typ. -78 dBm @ 48 Mbps
Typ. -74 dBm @ 54 Mbps
Receiver Sensitivity for 802.11n (2.4 GHz; measured at 2.437 GHz) Typ. -70 dBm @ MCS7 20 MHz
Typ. -69 dBm @ MCS15 20 MHz
Typ. -67 dBm @ MCS7 40 MHz
Typ. -67 dBm @ MCS15 40 MHz
WLAN Operation Mode Access point, Client, Client-Router, Master, Slave, Sniffer
Antenna External, 2/2 dBi, Omni-directional
Antenna Connectors 2 RP-SMA female
  • Ethernet Interface
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3af for PoE
IEEE 802.1Q for VLAN Tagging
IEEE 802.1X for authentication
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
PoE Ports (10/100/1000BaseT(X), RJ45 connector) 1
  • Ethernet Software Features
Management DHCP Server/Client, DNS, HTTP, IPv4, LLDP, Proxy ARP, SMTP, SNMPv1/v2c/v3, Syslog, TCP/IP, Telnet, UDP, VLAN, Wireless Search Utility, MXview, MXconfig
Routing Port forwarding, Static Route, NAT
Redundancy Protocols RSTP, STP
Security HTTPS/SSL, RADIUS, SSH
Time Management SNTP Client
  • Firewall
Filter ICMP, MAC address, IP protocol, Port-based
  • Serial Interface
Console Port RS-232, 8-pin RJ45
  • LED Interface
LED Indicators PWR1, PWR2, PoE, FAULT, STATE, SIGNAL, WLAN, LAN
  • Input/Output Interface
Digital Inputs 2
Max. input current: 8 mA
+13 to +30 V for state 1
+3 to -30 V for state 0
Alarm Contact Channels Relay output with current carrying capacity of 1 A @ 24 VDC
Buttons Reset button
  • Physical Characteristics
Housing Metal
IP Rating IP30
Dimensions 52.7 x 135 x 105 mm (2.08 x 5.32 x 4.13 in)
Weight 860 g (1.9 lb)
Installation DIN-rail mounting, Wall mounting (with optional kit)
  • Power Parameters
Input Current 0.6 A @ 12 VDC, 0.15 A @ 48 VDC
Input Voltage 12 to 48 VDC, Redundant dual inputs, 48 VDC Power-over-Ethernet
Power Connector 1 removable 10-contact terminal block(s)
Power Consumption 7.2 W (max.)
Reverse Polarity Protection Supported
  • Environmental Limits
Operating Temperature Standard Models: -25 to 60°C (-13 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
  • Standards and Certifications
EMC EN 61000-6-2/-6-4
EMI CISPR 32, FCC Part 15B Class B
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8 PFMF
Hazardous Locations ATEX, Class I Division 2, IECEx
Radio EN 300 328, EN 301 489-1/17, EN 301 893, FCC ID SLE-WAPN008, ANATEL, MIC, NCC, RCM, SRRC, WPC, KC
Safety EN 60950-1, UL 60950-1
Vibration IEC 60068-2-6
  • MTBF
Time 570,854 hrs
Standards Telcordia SR332