Producător: UNITRONICS
- ability to connect up to 16 I/O modules,
- remote configuration using UniLogic software,
- communication with PLC via EtherCAT.
Compatible I/O modules can be found at: https://www.elmark.com.ro/shop/sistem-i-o-modular
Preț de la 1.376,70 RON Net
Preț prea mare? Autentificați-vă și cumpărați mai ieftin
În stoc
Plasați comanda până la ora 12:00, iar coletul va fi expediat în aceeași zi
Livrare gratuita de la 500 RON
Promocja cenowa na model HDR-15-5
Modele
-
Model Disponibilitate Garanție Lista de dorințe Prețul tăuPrețul tău Cantitate articole AdăugareURB-EC1Uni. CAN Adapter 63 ModulesÎn stocGaranție: 1.376,70 RON1.693,34 RONIntră în cont pentru a vedea prețurile URB-EC1Uni. CAN Adapter 63 ModulesDisponibilitate:În stocPreț net:1.376,70 RON
Descriere
URB-EC1 is a remote EtherCAT (Remote I/O) expansion adapter that allows connection of up to 16 I/O modules to a master system. It is most commonly used for connection with:
- Unistream USC PLC (requires UAC-01EC2 module),
- Beckhoff PLC,
- other controllers with EtherCAT communication.
The use of remote I/O islands and decentralized systems allows for:
- reduced cabling costs (instead of running individual wires from the PLC to each sensor or device, a remote I/O island can be used to collect all signals from a distance and transmit them to the PLC with a single Ethernet cable),
- reduced installation time (fewer wires mean shorter installation time),
- easy diagnostics and maintenance (remote islands have built-in diagnostic functions, such as monitoring signal status, power, and communication, which streamlines troubleshooting),
- scalability and flexibility (you can easily add more I/O modules or connect another remote I/O island without changing the entire wiring system),
- reduced complexity,
- increased reliability (less electromagnetic interference and greater resistance to mechanical damage).
Specificație tehnică
Adapter Type | Slave node (EtherCAT ID) |
Maximum Number of Expansion Slots | 16 slots |
I/O Data Size |
Max. 256 input bytes / 256 output bytes In Unistream PLC: 128 bytes each |
Maximum Bus Line Length | Up to 100m from Ethernet hub/switch using CAT5 UTP/STP cable |
Maximum Number of Nodes in the Network | 65,535 (up to 8 adapters in Unistream) |
Transmission Speed | 10/100Mbps |
Bus Connection | 2 x RJ-45 |
MAC / IP Address | Not required |
Indicators | 4 LEDs 1 Green/Red - Module Status (MOD) 1 Green - Communication Status (RUN) 1 Red - Error Status (ERR) 1 Green/Red - I/O Expansion Module Status (IOS) |
System Power Supply | Supply voltage: 24VDC nominal, Class 2 Voltage range: 15~28.8VDC Protection: Reverse polarity protection |
Power Consumption | 40mA typical at 24VDC |
Current for I/O Modules | 1.0A at 5VDC |
Isolation | System power to internal logic: Not isolated System power to I/O driver: Isolated |
Working Area Power Supply | Supply voltage: 24VDC typical (Max. 28.8VDC) *Working area power supply voltage range depends on the I/O module series. Refer to the I/O module specification. |
Maximum Working Area Load Current | DC 8A max. |
I/O Wiring | Wire max. 2.0mm² (AWG 14) |
Weight | 76g |
Module Dimensions | 22mm x 109mm x 70mm |
Operating Temperature | -20°C to 60°C |