URB-TCP2

Remote IO Adapter - Modbus TCP, Ethernet/IP

Producător: UNITRONICS
Producător: UNITRONICS
  • ability to connect up to 6 I/O modules,
  • remote configuration using UniLogic, VisiLogic software,
  • communication with PLC via Modbus TCP and Ethernet/IP.

Compatible I/O modules can be found at: https://www.elmark.com.ro/shop/sistem-i-o-modular

Preț de la 1.077,80 RON Net

Preț prea mare? Autentificați-vă și cumpărați mai ieftin

În stoc

Plasați comanda până la ora 12:00, iar coletul va fi expediat în aceeași zi

Livrare gratuita de la 500 RON

Vezi 1 model

Promocja cenowa na model HDR-15-5

Modele

Accesorii

Descriere

URB-TCP is a Modbus TCP and Ethernet/IP remote expansion adapter that allows you to connect up to 6 I/O modules to a master system. It can be used for:
  • expanding the number of I/Os in a Vision/Unistream controller,
  • expanding the number of I/Os in any other controller with Modbus TCP or Ethernet/IP communication (e.g., Allen-Bradley, Omron).

Supported protocols:

  • Modbus TCP,
  • Modbus UDP,
  • Ethernet/IP,
  • TCP/UDP,
  • HTTP (Web Server).

The use of remote I/O adapters and decentralized systems allows for:

  • reduced cabling costs (instead of running individual wires from the PLC to each sensor or device, a remote I/O island can be used to collect all signals from a distance and transmit them to the PLC with a single Ethernet cable),
  • reduced installation time (fewer wires mean shorter installation time),
  • easy diagnostics and maintenance (remote I/O islands have built-in diagnostic functions, such as monitoring signal status, power, and communication, which streamline troubleshooting),
  • scalability and flexibility (you can easily add more I/O modules or another remote I/O island without changing the entire wiring system),
  • reduced complexity,
  • increased reliability (less electromagnetic interference and greater resistance to mechanical damage).
Check out how to connect the I/O island (URB-TCP/URB-TCP2) to the Unistream controller:



Check out how to connect the I/O island (URB-TCP/URB-TCP2) for operation with any system using Modbus TCP:

Specificație tehnică

Adapter type Slave node
Protocol MODBUS/TCP, MODBUS/UDP, HTTP, DHCP, 10 TCP connections, Ethernet/IP
Maximum number of expansion modules 6 slots
Maximum input/output data size 256 bytes of input data and 256 bytes of output data;
In Unistream PLC: 128 bytes each
Maximum bus line length Up to 100m from Ethernet hub/switch using CAT5 UTP/STP cable
Maximum number of nodes Limited by Ethernet specification
Transmission speed 10/100Mbps, auto-negotiation, full duplex
Interface connectors 2 x RJ-45 socket
IP address settings Via DHCP/BOOTP
IP address range xxx.xxx.xxx.1 ~ 253 (user area)
xxx.xxx.xxx.254 ~ 255 (reserved for IAP function)
LED indicators 4 LEDs
1 Green/Red - Module Status (MOD)
1 Green - Physical Connection (LINK)
1 Green - Data Exchange/Network Traffic (ACTIVE)
1 Green/Red - Expansion Module Status (IOS)
2 LEDs (for each RJ45 connector)
1 Yellow - Link/Activity
1 Green - Not used
System power supply Supply voltage: 24VDC nominal
Voltage range: 15~28.8VDC
Reverse polarity protection
Power consumption 75mA typical at 24VDC
Current for I/O modules 1.0A at 5VDC
Isolation System power to internal logic: Not isolated
System power to I/O driver: Isolated
Field power supply Supply voltage: 24VDC typical (Max. 32VDC)
*Field power range varies depending on the I/O module series.
Refer to the I/O module specification.
Maximum field power load current DC 8A max.
Weight 76g
Module size 22mm x 109mm x 70mm